NK (Alu. Alloy) & NKSS (S.S.) Series Rack & Pinion Pneu. Actuator
Sizing example of NUTORK double acting actuator:
Valve torque 100Nm plus 20% safety factor= 120Nm. Minimum operating pressure 6bar(87psig). By reading down the 6bar(87psig) column the figure below 120Nm is 135.0Nm, The model number shown in the left hand column is therefore NKD-092.
Valve torque 100Nm plus 20% safety factor= 120Nm. Minimum operating pressure 6bar(87psig). By reading down the 6bar(87psig) column the figure below 120Nm is 135.0Nm, The model number shown in the left hand column is therefore NKD-092.